add expand secrets and set volume expansion in examples update provisioner and resizer images to canary Signed-off-by: Oded Viner <oviner@redhat.com>
13 KiB
title
| title |
|---|
| NVMe-oF Block Storage |
NVMe-oF Block Storage
This feature is experimental
NVMe over Fabrics (NVMe-oF) allows RBD volumes to be exposed and accessed via the NVMe/TCP protocol. This enables both Kubernetes pods within the cluster and external clients outside the cluster to connect to Ceph block storage using standard NVMe-oF initiators, providing high-performance block storage access over the network.
Goals
The NVMe-oF integration in Rook serves two primary purposes:
-
External Client Access: Rook serves as a backend for external clients outside the cluster, enabling non-Kubernetes workloads to access Ceph block storage through standard NVMe-oF initiators. This allows organizations to leverage their Ceph storage infrastructure for both containerized and traditional workloads.
-
In-Cluster Consumption: Pods inside the Kubernetes cluster can consume storage via the NVMe-oF protocol, providing an alternative to traditional RBD mounts with potential performance benefits for certain workloads.
Both use cases are supported, allowing you to choose the appropriate access method based on your specific requirements and deployment scenarios.
For more background and design details, see the NVMe-oF gateway design doc. For the Ceph-CSI NVMe-oF design proposal, see the ceph-csi NVMe-oF proposal.
Prerequisites
This guide assumes a Rook cluster as explained in the Quickstart Guide.
Requirements
- Ceph Version: Ceph v20 (Tentacle) or later
- Disable the Ceph CSI operator: We are still updating the Ceph CSI operator with NVMe-oF support. Currently, it is required to disable the CSI operator to test NVMe-oF. In operator.yaml, set
ROOK_USE_CSI_OPERATOR: "false".
Step 1: Create a Ceph Block Pool
Before creating the NVMe-oF gateway, you need to create a CephBlockPool that will be used by the gateway:
apiVersion: ceph.rook.io/v1
kind: CephBlockPool
metadata:
name: nvmeof
namespace: rook-ceph
spec:
failureDomain: host
replicated:
size: 3
Create the pool:
kubectl create -f deploy/examples/csi/nvmeof/nvmeof-pool.yaml
Step 2: Create the NVMe-oF Gateway
The CephNVMeOFGateway CRD manages the NVMe-oF gateway infrastructure. The operator will automatically create the following resources:
- Service: One per gateway instance for service discovery
- Deployment: One per gateway instance running the NVMe-oF gateway daemon
Create the gateway:
apiVersion: ceph.rook.io/v1
kind: CephNVMeOFGateway
metadata:
name: nvmeof
namespace: rook-ceph
spec:
# Container image for the NVMe-oF gateway daemon
image: quay.io/ceph/nvmeof:1.5
# Pool name that will be used by the NVMe-oF gateway
pool: nvmeof
# ANA (Asymmetric Namespace Access) group name
group: group-a
# Number of gateway instances to run
instances: 1
hostNetwork: false
Apply the gateway configuration:
kubectl create -f deploy/examples/nvmeof-test.yaml
Verify the gateway is running:
kubectl get pod -n rook-ceph -l app=rook-ceph-nvmeof
Example Output
NAME READY STATUS RESTARTS AGE
rook-ceph-nvmeof-nvmeof-a-85844ff6b8-4r8gj 1/1 Running 0 91s
Step 4: Deploy the NVMe-oF CSI Driver
The NVMe-oF CSI driver handles dynamic provisioning of volumes. Deploy the CSI provisioner with the NVMe-oF driver.
Deploy the NVMe-oF CSI provisioner from the example manifest:
kubectl create -f deploy/examples/csi/nvmeof/provisioner.yaml
Verify the CSI provisioner pod is running:
kubectl get pods -n rook-ceph -l app=csi-nvmeofplugin-provisioner
Example Output
NAME READY STATUS RESTARTS AGE
csi-nvmeofplugin-provisioner-65b4fbbc8-jjsqj 4/4 Running 0 75s
Step 5: Create the StorageClass
Create a StorageClass that uses the NVMe-oF CSI driver. You'll need to gather the following information from the gateway:
- nvmeofGatewayAddress: A stable address for the gateway management API
- nvmeofGatewayPort: The gateway port (default: 5500)
- listeners: A JSON array containing listener information for each gateway instance
Discover the values to use in the StorageClass:
-
nvmeofGatewayAddress: Use the Service
CLUSTER-IP.kubectl get service -n rook-ceph rook-ceph-nvmeof-nvmeof-aExample Output
NAME TYPE CLUSTER-IP EXTERNAL-IP PORT(S) AGE rook-ceph-nvmeof-nvmeof-a ClusterIP 10.106.98.71 <none> 4420/TCP,5500/TCP,5499/TCP,8009/TCP 24m -
listeners.address: Use the gateway pod IP.
kubectl get pods -n rook-ceph -l app=rook-ceph-nvmeof -o wideExample Output
NAME READY STATUS RESTARTS AGE IP NODE NOMINATED NODE READINESS GATES rook-ceph-nvmeof-nvmeof-a-5fd6cd4d46-mrbwk 1/1 Running 0 26m 10.244.0.16 minikube <none> <none> -
listeners.hostname: Use the gateway deployment name.
kubectl get deployments.apps -n rook-ceph -l app=rook-ceph-nvmeofExample Output
NAME READY UP-TO-DATE AVAILABLE AGE rook-ceph-nvmeof-nvmeof-a 1/1 1 1 27m
Create the StorageClass:
apiVersion: storage.k8s.io/v1
kind: StorageClass
metadata:
name: ceph-nvmeof
parameters:
clusterID: rook-ceph
pool: nvmeof
subsystemNQN: nqn.2016-06.io.spdk:cnode1.rook-ceph
# Management API - talks to gateway to create subsystems/namespaces
nvmeofGatewayAddress: "10.106.98.71"
nvmeofGatewayPort: "5500"
# Data Plane - worker nodes connect here for actual I/O
# List ALL gateway pods for HA and multipath
listeners: |
[
{
"address": "10.244.0.16",
"port": 4420,
"hostname": "rook-ceph-nvmeof-nvmeof-a"
}
]
csi.storage.k8s.io/provisioner-secret-name: rook-csi-rbd-provisioner
csi.storage.k8s.io/provisioner-secret-namespace: rook-ceph
csi.storage.k8s.io/node-stage-secret-name: rook-csi-rbd-node
csi.storage.k8s.io/node-stage-secret-namespace: rook-ceph
csi.storage.k8s.io/controller-expand-secret-name: rook-csi-rbd-provisioner
csi.storage.k8s.io/controller-expand-secret-namespace: rook-ceph
csi.storage.k8s.io/node-expand-secret-name: rook-csi-rbd-node
csi.storage.k8s.io/node-expand-secret-namespace: rook-ceph
imageFormat: "2"
imageFeatures: layering,deep-flatten,exclusive-lock,object-map,fast-diff
provisioner: nvmeof.csi.ceph.com
reclaimPolicy: Delete
volumeBindingMode: Immediate
allowVolumeExpansion: true
Create the StorageClass:
kubectl create -f deploy/examples/csi/nvmeof/storageclass.yaml
Step 6: Create a PersistentVolumeClaim
Create a PVC using the NVMe-oF storage class:
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: nvmeof-external-volume
namespace: default
spec:
storageClassName: ceph-nvmeof
accessModes:
- ReadWriteOnce
resources:
requests:
storage: 128Mi
!!! note This PVC is created for CSI driver provisioning. The volume will be accessible via NVMe-oF protocol by both Kubernetes pods within the cluster and external clients outside the cluster using standard NVMe-oF initiators.
Create the PVC:
kubectl create -f deploy/examples/csi/nvmeof/pvc.yaml
Verify the PVC is bound:
kubectl get pvc nvmeof-external-volume
Example Output
NAME STATUS VOLUME CAPACITY ACCESS MODES STORAGECLASS AGE
nvmeof-external-volume Bound pvc-b4108580-5cfa-46d3-beff-320088a5bf3c 128Mi RWO ceph-nvmeof 20m
Step 7: Deploy the NVMe-oF CSI Node Plugin
Deploy the NVMe-oF CSI node plugin:
kubectl create -f deploy/examples/csi/nvmeof/node-plugin.yaml
Verify the node plugin pod is running:
kubectl get pods -n rook-ceph -l app=nvmeof.csi.ceph.com-nodeplugin
Example Output
NAME READY STATUS RESTARTS AGE
nvmeof.csi.ceph.com-nodeplugin-xnm82 2/2 Running 0 31h
Step 8: Accessing Volumes via NVMe-oF
Once the PVC is created and bound, the volume is available via NVMe-oF. The volume can be accessed by both Kubernetes pods within the cluster and external clients outside the cluster.
Access from Kubernetes Pods
Kubernetes pods can consume NVMe-oF volumes by mounting the PVC directly. The CSI driver handles the NVMe-oF connection automatically when the pod mounts the volume.
Create a sample pod that mounts the PVC:
kubectl create -f deploy/examples/csi/nvmeof/pod.yaml
Verify the pod is running:
kubectl get pods -n default
Example Output
NAME READY STATUS RESTARTS AGE
nvmeof-test-pod 1/1 Running 0 29h
Access from External Clients
External clients outside the Kubernetes cluster can connect to the gateway using standard NVMe-oF procedures.
Prerequisites for External Clients
- NVMe-oF Initiator: The client must have the
nvme-tcpkernel module loaded andnvme-cliinstalled - Network Access: The client must be able to reach the gateway service IP and ports
Discover Subsystems
From the external client, discover available NVMe-oF subsystems:
nvme discover -t tcp -a <gateway-service-ip> -s 5500
Replace <gateway-service-ip> with the gateway service ClusterIP or an accessible endpoint.
Connect to Subsystem
Connect to the discovered subsystem:
nvme connect -t tcp -n <subsystem-nqn> -a <gateway-ip> -s 5500
Replace:
<subsystem-nqn>with thesubsystemNQNvalue from your StorageClass (e.g.,nqn.2016-06.io.spdk:cnode1.rook-ceph)<gateway-ip>with the gateway service IP or pod IP
Access the Volume
Once connected, the NVMe namespace will appear as a block device on the client:
lsblk | grep nvme
The device will typically appear as /dev/nvmeXnY where X is the controller number and Y is the namespace ID.
Format and Mount (Optional)
If you want to format and mount the device:
# Format the device
sudo mkfs.ext4 /dev/nvmeXnY
# Mount the device
sudo mkdir /mnt/nvmeof
sudo mount /dev/nvmeXnY /mnt/nvmeof
High Availability
For production deployments, configure multiple gateway instances for high availability:
- Increase Gateway Instances: Set
instances: 2or higher in theCephNVMeOFGatewayspec - Update StorageClass Listeners: Add all gateway instance addresses and instance names to the
listenersarray - Load Balancing: Each gateway instance has its own Service; list all of them to support multipath/HA
Example with multiple instances:
spec:
instances: 2
# ... other settings
Then update the StorageClass listeners to include all gateway instances/services:
listeners: |
[
{
"address": "10.99.212.218",
"port": 4420,
"hostname": "rook-ceph-nvmeof-nvmeof-a"
},
{
"address": "10.99.212.219",
"port": 4420,
"hostname": "rook-ceph-nvmeof-nvmeof-b"
}
]
Troubleshooting
Check Gateway Pod Logs
kubectl logs -n rook-ceph -l app=rook-ceph-nvmeof --tail=100
Check CSI Provisioner Logs
kubectl logs -n rook-ceph -l app=csi-nvmeofplugin-provisioner --tail=100
Verify Gateway Service
kubectl describe service -n rook-ceph rook-ceph-nvmeof-my-nvmeof-0
Check PVC Events
kubectl describe pvc nvmeof-external-volume
Verify Ceph CSI Config
Ensure the rook-ceph-csi-config ConfigMap exists and contains the cluster configuration:
kubectl get configmap -n rook-ceph rook-ceph-csi-config -o yaml
Teardown
!!! warning Deleting the PVC will also delete the underlying RBD image and NVMe namespace. Ensure you have backups if needed.
To clean up all the artifacts created:
# Delete the test pod
kubectl delete -f deploy/examples/csi/nvmeof/pod.yaml
# Delete the PVC
kubectl delete pvc nvmeof-external-volume
# Delete the StorageClass
kubectl delete storageclass ceph-nvmeof
# Delete the NVMe-oF CSI node plugin
kubectl delete -f deploy/examples/csi/nvmeof/node-plugin.yaml
# Delete the NVMe-oF CSI provisioner (includes ServiceAccount/RBAC)
kubectl delete -f deploy/examples/csi/nvmeof/provisioner.yaml
# Delete the NVMe-oF gateway
kubectl delete -n rook-ceph cephnvmeofgateway.ceph.rook.io my-nvmeof
# Delete the block pool (optional)
kubectl delete -n rook-ceph cephblockpool.ceph.rook.io nvmeof