title: NVMe-oF Block Storage
|
|
---
|
|
# NVMe-oF Block Storage
|
|
|
|
**This feature is experimental**
|
|
|
|
NVMe over Fabrics (NVMe-oF) allows RBD volumes to be exposed and accessed via the NVMe/TCP protocol. This enables both Kubernetes pods within the cluster and external clients outside the cluster to connect to Ceph block storage using standard NVMe-oF initiators, providing high-performance block storage access over the network.
|
|
|
|
## Goals
|
|
|
|
The NVMe-oF integration in Rook serves two primary purposes:
|
|
|
|
1. **External Client Access**: Rook serves as a backend for external clients outside the cluster, enabling non-Kubernetes workloads to access Ceph block storage through standard NVMe-oF initiators. This allows organizations to leverage their Ceph storage infrastructure for both containerized and traditional workloads.
|
|
|
|
2. **In-Cluster Consumption**: Pods inside the Kubernetes cluster can consume storage via the NVMe-oF protocol, providing an alternative to traditional RBD mounts with potential performance benefits for certain workloads.
|
|
|
|
Both use cases are supported, allowing you to choose the appropriate access method based on your specific requirements and deployment scenarios.
|
|
|
|
For more background and design details, see the [NVMe-oF gateway design doc](https://github.com/rook/rook/blob/master/design/ceph/ceph-nvmeof-gateway.md).
|
|
For the Ceph-CSI NVMe-oF design proposal, see the [ceph-csi NVMe-oF proposal](https://github.com/ceph/ceph-csi/blob/devel/docs/design/proposals/nvme-of.md).
|
|
|
|
## Prerequisites
|
|
|
|
This guide assumes a Rook cluster as explained in the [Quickstart Guide](../../Getting-Started/quickstart.md).
|
|
|
|
### Requirements
|
|
|
|
- **Ceph Version**: Ceph v20 (Tentacle) or later
|
|
|
|
## Step 1: Create a Ceph Block Pool
|
|
|
|
Before creating the NVMe-oF gateway, you need to create a CephBlockPool that will be used by the gateway:
|
|
|
|
```yaml
|
|
apiVersion: ceph.rook.io/v1
|
|
kind: CephBlockPool
|
|
metadata:
|
|
name: nvmeof
|
|
namespace: rook-ceph
|
|
spec:
|
|
failureDomain: host
|
|
replicated:
|
|
size: 3
|
|
```
|
|
|
|
Create the pool:
|
|
|
|
```console
|
|
kubectl create -f deploy/examples/csi/nvmeof/nvmeof-pool.yaml
|
|
```
|
|
|
|
## Step 2: Create the NVMe-oF Gateway
|
|
|
|
The `CephNVMeOFGateway` CRD manages the NVMe-oF gateway infrastructure. The operator will automatically create the following resources:
|
|
|
|
- **Service**: One per gateway instance for service discovery
|
|
- **Deployment**: One per gateway instance running the NVMe-oF gateway daemon
|
|
|
|
Create the gateway:
|
|
|
|
```yaml
|
|
apiVersion: ceph.rook.io/v1
|
|
kind: CephNVMeOFGateway
|
|
metadata:
|
|
name: nvmeof
|
|
namespace: rook-ceph
|
|
spec:
|
|
# Container image for the NVMe-oF gateway daemon
|
|
image: quay.io/ceph/nvmeof:1.5
|
|
# Pool name that will be used by the NVMe-oF gateway
|
|
pool: nvmeof
|
|
# ANA (Asymmetric Namespace Access) group name
|
|
group: group-a
|
|
# Number of gateway instances to run
|
|
instances: 1
|
|
hostNetwork: false
|
|
```
|
|
|
|
Apply the gateway configuration:
|
|
|
|
```console
|
|
kubectl create -f deploy/examples/nvmeof-test.yaml
|
|
```
|
|
|
|
Verify the gateway is running:
|
|
|
|
```console
|
|
kubectl get pod -n rook-ceph -l app=rook-ceph-nvmeof
|
|
```
|
|
|
|
**Example Output**
|
|
|
|
```console
|
|
NAME READY STATUS RESTARTS AGE
|
|
rook-ceph-nvmeof-nvmeof-a-85844ff6b8-4r8gj 1/1 Running 0 91s
|
|
```
|
|
|
|
## Step 3: Deploy the NVMe-oF CSI Driver via CSI Operator
|
|
|
|
The NVMe-oF CSI driver is deployed via the ceph-csi operator.
|
|
|
|
Apply the `Driver` CR for NVMe-oF that will trigger the creation of the
|
|
Ceph-CSI/NVMe-oF deployment and daemonset:
|
|
|
|
```console
|
|
kubectl create -f deploy/examples/csi/nvmeof/driver.yaml
|
|
```
|
|
|
|
Verify the CSI operator created the controller and node plugins:
|
|
|
|
```console
|
|
kubectl get pods -n rook-ceph | grep nvmeof
|
|
```
|
|
|
|
**Example Output**
|
|
|
|
```console
|
|
rook-ceph.nvmeof.csi.ceph.com-ctrlplugin-d9d77fb7c-kkl28 5/5 Running 0 60s
|
|
rook-ceph.nvmeof.csi.ceph.com-nodeplugin-xvt5g 2/2 Running 0 60s
|
|
```
|
|
|
|
## Step 4: Create the StorageClass
|
|
|
|
Create a StorageClass that uses the NVMe-oF CSI driver.
|
|
|
|
```yaml
|
|
apiVersion: storage.k8s.io/v1
|
|
kind: StorageClass
|
|
metadata:
|
|
name: ceph-nvmeof
|
|
parameters:
|
|
clusterID: rook-ceph
|
|
pool: nvmeof
|
|
subsystemNQN: nqn.2016-06.io.spdk:cnode1.rook-ceph
|
|
nvmeofGatewayAddress: "rook-ceph-nvmeof-nvmeof-a.rook-ceph.svc.cluster.local"
|
|
nvmeofGatewayPort: "5500"
|
|
listeners: |
|
|
[
|
|
{
|
|
"hostname": "rook-ceph-nvmeof-nvmeof-a"
|
|
}
|
|
]
|
|
csi.storage.k8s.io/provisioner-secret-name: rook-csi-rbd-provisioner
|
|
csi.storage.k8s.io/provisioner-secret-namespace: rook-ceph
|
|
csi.storage.k8s.io/node-stage-secret-name: rook-csi-rbd-node
|
|
csi.storage.k8s.io/node-stage-secret-namespace: rook-ceph
|
|
csi.storage.k8s.io/controller-expand-secret-name: rook-csi-rbd-provisioner
|
|
csi.storage.k8s.io/controller-expand-secret-namespace: rook-ceph
|
|
csi.storage.k8s.io/controller-modify-secret-name: rook-csi-rbd-provisioner
|
|
csi.storage.k8s.io/controller-modify-secret-namespace: rook-ceph
|
|
csi.storage.k8s.io/node-expand-secret-name: rook-csi-rbd-node
|
|
csi.storage.k8s.io/node-expand-secret-namespace: rook-ceph
|
|
imageFormat: "2"
|
|
imageFeatures: layering,deep-flatten,exclusive-lock,object-map,fast-diff
|
|
provisioner: rook-ceph.nvmeof.csi.ceph.com
|
|
reclaimPolicy: Delete
|
|
volumeBindingMode: Immediate
|
|
allowVolumeExpansion: true
|
|
```
|
|
|
|
!!! note
|
|
The provisioner name `rook-ceph.nvmeof.csi.ceph.com` is prefixed
|
|
with the operator namespace.
|
|
|
|
```console
|
|
kubectl create -f deploy/examples/csi/nvmeof/storageclass.yaml
|
|
```
|
|
|
|
## Step 5: Create a PersistentVolumeClaim
|
|
|
|
Create a PVC using the NVMe-oF storage class:
|
|
|
|
```yaml
|
|
apiVersion: v1
|
|
kind: PersistentVolumeClaim
|
|
metadata:
|
|
name: nvmeof-external-volume
|
|
namespace: default
|
|
spec:
|
|
storageClassName: ceph-nvmeof
|
|
accessModes:
|
|
- ReadWriteOnce
|
|
resources:
|
|
requests:
|
|
storage: 128Mi
|
|
```
|
|
|
|
!!! note
|
|
This PVC is created for CSI driver provisioning. The volume will be accessible via NVMe-oF protocol by both Kubernetes pods within the cluster and external clients outside the cluster using standard NVMe-oF initiators.
|
|
|
|
Create the PVC:
|
|
|
|
```console
|
|
kubectl create -f deploy/examples/csi/nvmeof/pvc.yaml
|
|
```
|
|
|
|
Verify the PVC is bound:
|
|
|
|
```console
|
|
kubectl get pvc nvmeof-external-volume
|
|
```
|
|
|
|
**Example Output**
|
|
|
|
```console
|
|
NAME STATUS VOLUME CAPACITY ACCESS MODES STORAGECLASS AGE
|
|
nvmeof-external-volume Bound pvc-b4108580-5cfa-46d3-beff-320088a5bf3c 128Mi RWO ceph-nvmeof 20m
|
|
```
|
|
|
|
## Step 6: Create a Pod
|
|
|
|
Create a pod that consumes the NVMe-oF volume:
|
|
|
|
```console
|
|
kubectl create -f deploy/examples/csi/nvmeof/pod.yaml
|
|
```
|
|
|
|
Verify the pod is running:
|
|
|
|
```console
|
|
kubectl get pods -n default nvmeof-test-pod
|
|
```
|
|
|
|
**Example Output**
|
|
|
|
```console
|
|
NAME READY STATUS RESTARTS AGE
|
|
nvmeof-test-pod 1/1 Running 0 60s
|
|
```
|
|
|
|
## Step 7: Accessing Volumes via NVMe-oF
|
|
|
|
Once the PVC is created and bound, the volume is available via
|
|
NVMe-oF. The volume can be accessed by both Kubernetes pods within
|
|
the cluster and external clients outside the cluster.
|
|
|
|
### Access from External Clients
|
|
|
|
External clients outside the Kubernetes cluster can connect to the gateway using standard NVMe-oF procedures.
|
|
|
|
#### Prerequisites for External Clients
|
|
|
|
- **NVMe-oF Initiator**: The client must have the `nvme-tcp` kernel module loaded and `nvme-cli` installed
|
|
- **Network Access**: The client must be able to reach the gateway service IP and ports
|
|
|
|
#### Discover Subsystems
|
|
|
|
From the external client, discover available NVMe-oF subsystems:
|
|
|
|
```bash
|
|
nvme discover -t tcp -a <gateway-service-ip> -s 5500
|
|
```
|
|
|
|
Replace `<gateway-service-ip>` with the gateway service ClusterIP or an accessible endpoint.
|
|
|
|
#### Connect to Subsystem
|
|
|
|
Connect to the discovered subsystem:
|
|
|
|
```bash
|
|
nvme connect -t tcp -n <subsystem-nqn> -a <gateway-ip> -s 5500
|
|
```
|
|
|
|
Replace:
|
|
|
|
- `<subsystem-nqn>` with the `subsystemNQN` value from your StorageClass (e.g., `nqn.2016-06.io.spdk:cnode1.rook-ceph`)
|
|
- `<gateway-ip>` with the gateway service IP or pod IP
|
|
|
|
#### Access the Volume
|
|
|
|
Once connected, the NVMe namespace will appear as a block device on the client:
|
|
|
|
```bash
|
|
lsblk | grep nvme
|
|
```
|
|
|
|
The device will typically appear as `/dev/nvmeXnY` where X is the controller number and Y is the namespace ID.
|
|
|
|
#### Format and Mount (Optional)
|
|
|
|
If you want to format and mount the device:
|
|
|
|
```bash
|
|
# Format the device
|
|
sudo mkfs.ext4 /dev/nvmeXnY
|
|
|
|
# Mount the device
|
|
sudo mkdir /mnt/nvmeof
|
|
sudo mount /dev/nvmeXnY /mnt/nvmeof
|
|
```
|
|
|
|
## High Availability
|
|
|
|
For production deployments, configure multiple gateway instances for high availability:
|
|
|
|
1. **Increase Gateway Instances**: Set `instances: 2` or higher in the `CephNVMeOFGateway` spec
|
|
2. **Update StorageClass Listeners**: Add all gateway deployment hostnames to the `listeners` array
|
|
3. **Load Balancing**: Each gateway instance has its own Service; list all of them to support multipath/HA
|
|
|
|
Example with multiple instances:
|
|
|
|
```yaml
|
|
spec:
|
|
instances: 2
|
|
# ... other settings
|
|
```
|
|
|
|
Then update the StorageClass `listeners` to include all gateway
|
|
hostnames:
|
|
|
|
```yaml
|
|
listeners: |
|
|
[
|
|
{
|
|
"hostname": "rook-ceph-nvmeof-nvmeof-a"
|
|
},
|
|
{
|
|
"hostname": "rook-ceph-nvmeof-nvmeof-b"
|
|
}
|
|
]
|
|
```
|
|
|
|
## Troubleshooting
|
|
|
|
### Check Gateway Pod Logs
|
|
|
|
```console
|
|
kubectl logs -n rook-ceph -l app=rook-ceph-nvmeof --tail=100
|
|
```
|
|
|
|
### Check CSI Controller Plugin Logs
|
|
|
|
```console
|
|
kubectl logs -n rook-ceph deploy/rook-ceph.nvmeof.csi.ceph.com-ctrlplugin --tail=100
|
|
```
|
|
|
|
### Verify Gateway Service
|
|
|
|
```console
|
|
kubectl describe service -n rook-ceph rook-ceph-nvmeof-nvmeof-a
|
|
```
|
|
|
|
### Check PVC Events
|
|
|
|
```console
|
|
kubectl describe pvc nvmeof-external-volume
|
|
```
|
|
|
|
### Verify Ceph CSI Config
|
|
|
|
Ensure the `rook-ceph-csi-config` ConfigMap exists and contains the cluster configuration:
|
|
|
|
```console
|
|
kubectl get configmap -n rook-ceph rook-ceph-csi-config -o yaml
|
|
```
|
|
|
|
## Teardown
|
|
|
|
!!! warning
|
|
Deleting the PVC will also delete the underlying RBD image and NVMe namespace. Ensure you have backups if needed.
|
|
|
|
To clean up all the artifacts created:
|
|
|
|
```console
|
|
# Delete the test pod
|
|
kubectl delete -f deploy/examples/csi/nvmeof/pod.yaml
|
|
|
|
# Delete the PVC
|
|
kubectl delete pvc nvmeof-external-volume
|
|
|
|
# Delete the StorageClass
|
|
kubectl delete storageclass ceph-nvmeof
|
|
|
|
# Delete the NVMe-oF CSI operator resources
|
|
kubectl delete -f deploy/examples/csi/nvmeof/csi-operator-nvmeof.yaml
|
|
|
|
# Delete the NVMe-oF gateway
|
|
kubectl delete -f deploy/examples/nvmeof-test.yaml
|
|
|
|
# Delete the block pool (optional)
|
|
kubectl delete -f deploy/examples/csi/nvmeof/nvmeof-pool.yaml
|
|
```
|
|
|
|
## References
|
|
|
|
- [Ceph NVMe-oF Documentation](https://docs.ceph.com/en/latest/rbd/nvmeof-overview/)
|
|
- [Ceph NVMe-oF Initiator Guide](https://docs.ceph.com/en/latest/rbd/nvmeof-initiator-linux/)
|
|
- [Ceph CSI NVMe-oF Support](https://github.com/ceph/ceph-csi/blob/devel/docs/design/proposals/nvme-of.md)
|