Fix incorrect battery unit on paired Guardian sensors (#75402)

This commit is contained in:
Aaron Bach
2022-07-22 03:24:07 -06:00
committed by GitHub
parent f0eea62c1e
commit 630c28d253
4 changed files with 6 additions and 6 deletions

View File

@ -3,7 +3,7 @@
"name": "Elexa Guardian",
"config_flow": true,
"documentation": "https://www.home-assistant.io/integrations/guardian",
"requirements": ["aioguardian==2022.03.2"],
"requirements": ["aioguardian==2022.07.0"],
"zeroconf": ["_api._udp.local."],
"codeowners": ["@bachya"],
"iot_class": "local_polling",

View File

@ -10,7 +10,7 @@ from homeassistant.components.sensor import (
SensorStateClass,
)
from homeassistant.config_entries import ConfigEntry
from homeassistant.const import PERCENTAGE, TEMP_FAHRENHEIT, TIME_MINUTES
from homeassistant.const import ELECTRIC_POTENTIAL_VOLT, TEMP_FAHRENHEIT, TIME_MINUTES
from homeassistant.core import HomeAssistant, callback
from homeassistant.helpers.dispatcher import async_dispatcher_connect
from homeassistant.helpers.entity import EntityCategory
@ -46,9 +46,9 @@ PAIRED_SENSOR_DESCRIPTIONS = (
SensorEntityDescription(
key=SENSOR_KIND_BATTERY,
name="Battery",
device_class=SensorDeviceClass.BATTERY,
device_class=SensorDeviceClass.VOLTAGE,
entity_category=EntityCategory.DIAGNOSTIC,
native_unit_of_measurement=PERCENTAGE,
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
),
SensorEntityDescription(
key=SENSOR_KIND_TEMPERATURE,

View File

@ -162,7 +162,7 @@ aioftp==0.12.0
aiogithubapi==22.2.4
# homeassistant.components.guardian
aioguardian==2022.03.2
aioguardian==2022.07.0
# homeassistant.components.harmony
aioharmony==0.2.9

View File

@ -146,7 +146,7 @@ aioflo==2021.11.0
aiogithubapi==22.2.4
# homeassistant.components.guardian
aioguardian==2022.03.2
aioguardian==2022.07.0
# homeassistant.components.harmony
aioharmony==0.2.9