Fix incorrect Notion battery state calculation (#43108)

* Fix incorrect Notion battery state calculation

* Both cases
This commit is contained in:
Aaron Bach
2020-11-12 10:47:47 -07:00
committed by Paulus Schoutsen
parent 6cfbf294d1
commit 86a26d1a7c

View File

@@ -79,14 +79,10 @@ class NotionBinarySensor(NotionEntity, BinarySensorEntity):
"""Fetch new state data for the sensor."""
task = self.coordinator.data["tasks"][self._task_id]
if task["task_type"] == SENSOR_BATTERY:
self._state = self.coordinator.data["tasks"][self._task_id]["status"][
"data"
]["to_state"]
else:
self._state = self.coordinator.data["tasks"][self._task_id]["status"][
"value"
]
if "value" in task["status"]:
self._state = task["status"]["value"]
elif task["task_type"] == SENSOR_BATTERY:
self._state = task["status"]["data"]["to_state"]
@property
def is_on(self) -> bool:
@@ -94,7 +90,7 @@ class NotionBinarySensor(NotionEntity, BinarySensorEntity):
task = self.coordinator.data["tasks"][self._task_id]
if task["task_type"] == SENSOR_BATTERY:
return self._state != "critical"
return self._state == "critical"
if task["task_type"] in (
SENSOR_DOOR,
SENSOR_GARAGE_DOOR,