Previously arbiter monitors were allowed to failover in supported versions
of Ceph. This behaviour regressed. Since all supported versions of Ceph now
support this, we no longer need to check this at all.
Signed-off-by: Grant Fleming <gfleming@evroc.com>
(cherry picked from commit cdf692d227)
The devel images have been fairly stable for Rook to test
against, but on occasion there are regressions from
Ceph development that affect the Rook CI. For stability during
Rook development, use the latest stable version of ceph for
PRs, master, and release tests. The daily CI will still use
the devel images from Ceph.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit b229240faa)
The upgrade of the mds daemons pauses to wait for the
stopping of standby daemons before the filesystem upgrade
is completed. If there are multiple filesystems, there
could be standbys for other filesystems that will not be
stopped at the time of the upgrade of another filesystem.
Thus, the standbys may not upgrade and be stuck on the
previous version. Now, the standby upgrade will only wait
for standbys for the same filesystem.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit 99d60c5bba)
If the cmd-reporter key is set under the resources
element in the CephCluster CR, the memory and cpu request
and limits will be set on the ceph detect version job
and network job accordingly.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit f489f99e13)
For nodes that are explicitly requested for deploying
OSDs, they will be skipped temporarily if not
schedulable or not ready. A future reconcile is
expected to schedule them. Allow the OSDs to be
scheduled even on these nodes that are temporarily
down, even if it blocks the reconcile from completing.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit 7fbe4e7db5)
If there are multiple clusters, `dataDirHostPath` must be unique
for each cluster. However, it's not documented yet.
In addition, `ceph-teardown.md` was also updated because
the original document assumes that `dataDirHostPath` is
`/var/lib/rook` and the files for a cluster `rook-ceph` is
under `/var/lib/rook/rook-ceph`.
related issue:
https://github.com/rook/rook/issues/14790
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
(cherry picked from commit 62d99330d6)
The version checks for the csi driver are removed now
since they are all obsolete. The K8s version and cephcsi
versions are no longer checked. Anyway, the move to the
csi operator would take ownership of version checks
needed in the future, so for now we simplify rook
deployment of the csi driver.
Signed-off-by: Travis Nielsen <tnielsen@redhat.com>
(cherry picked from commit 2ff429e479)
some of the links have the full path
which is not working in the doc server,
but works locally
Signed-off-by: parth-gr <partharora1010@gmail.com>
(cherry picked from commit d061382661)
`encryption-pvc-kms-ibm-kp` workflow replaces the name of ceph-image.
Since the dest value is always empty by mistake, this workflow
always fails.
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
(cherry picked from commit 36721edae8)
When generating the HTTP client used for RGW admin ops, use both system
certs as well as the user-given cert.
As a real world example, admins may use ACME to rotate Letsencrypt certs
every 2 months. For an external CephObjectStore, the cert used by Rook
and RGW may not be rotated at the same time. This can cause the Rook
operator to fail CephObjectStore reconciliation until both certs agree.
When Rook also relies on system certs in the container, Rook's
reconciliation will not have reconciliation failures because
Letsencrypt's well-known and trusted root certificates can be loaded
from the system to validate the RGW's newly-rotated cert.
Signed-off-by: Blaine Gardner <blaine.gardner@ibm.com>
(cherry picked from commit 7bb72a0171)
The /run/udev directory is now mounted in the OSD init container. This change
is necessary because `ceph-volume activate` needs access to /run/udev [1] in order
to properly handle devices. Without this mount, `ceph-volume activate` could
fail to discover devices during OSD initialization.
[1] https://github.com/ceph/ceph/commit/c2e8c295dc46f1bd74861feb163d9d82f8bb5509
Signed-off-by: Guillaume Abrioux <gabrioux@ibm.com>
(cherry picked from commit dbcd0d46dd)
Signed-off-by: Satoru Takeuchi <satoru.takeuchi@gmail.com>
This is similar to #14052 we did for radosnamespace
and this is an extension to support cleanup
at the blockpool level to cleanup the images
and the snapshots in a pool.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
(cherry picked from commit 4e29717317)
PR #14883 fixed the codegen workflow but introduced a comment
that is simply wrong.
This change rectifies this mistake by removing the comment.
Signed-off-by: Michael Adam <obnox@samba.org>
(cherry picked from commit 714f80a80a)